This drawing shows a pad footing reinforcement detail in section and plan. The footing contains longitudinal reinforcement bars and transverse stirrups, with notes such as 6 Ø16 mm and e Ø6 mm c/20 cm. The column starter bars are shown rising through the footing and above the soil level line.