This detail shows an interior floor expansion joint in section, with glazed tile flooring on top and the joint centered between two floor areas. The drawing highlights the sealant profile, rounded back-up, compressible back-up, and the note about joint width being four times the expected movement. It is a clean technical section focused on how the joint is formed and sealed.