This detail drawing shows a floor-to-floor settlement joint for a ceramic-to-ceramic finish. The section illustrates the layered floor build-up above an RC slab, with ceramic tiles, sand and mortar, a DPC layer, and plastered soffit below. The central joint is formed with backing board, joint filler, and mastic sealant to allow movement between the two slab edges.