Annotated section at a skylight-to-metal-roof junction. The drawing identifies laminated glass in an aluminium frame above metal flashing and a ventilation opening. Below, a Z-profile roofing support, waterproof membrane, timber insert, thermal insulation and vapour barrier meet the lower rafter structure. Leaders and hatches distinguish the glazing, raised edge and layered sloping roof within the complete junction.