Floor expansion-joint section for mechanical rooms, with labels identifying an epoxy finish, fibre-containing sloped screed, bituminous waterproofing membrane and supporting slab. A surface joint profile bridges the gap, while the membrane turns downward within it. Distinct hatching and the drawn fixing position clarify the relationship between floor layers, joint edges and the central separation.